| Applicable camera |
TAKEX FC series and NC series camera |
| Trigger input |
Connect to 9-pin male model D-SUB connector on back
panel (3 systems)
Voltage at input portion is pulled up to 5V at inner 4.7kΩ.
(Excluding photo split trigger input)
Level range H = 3.7 to 5.5V and L = -0.5 to 0.5V
(High level trigger input)
H = 2.5 to 3.5V and L = -0.5 to 0.5V
(Low level trigger input)
OFF = 0 to 0.5mA and ON = 8.0 to 10mA
(Photo split trigger input)
Negative logic input and minimum trigger input width 10 µsec |
Voltage at input portion is pulled up to 5V using inner
4.7kΩ.
(High level trigger input)
Level range H = 3.7 to 5.5V and L = -0.5 to 0.5V
Negative logic input and minimum trigger input width 10µsec
(Low-level trigger input and photo split trigger input are equipped other than
this.) |
HD/VD input
RS-232C input |
Connect to 9-pin female type D-SUB connector on back
panel and relayed to camera.
Connect 9-pin female type D-SUB connector on back panel and relayed to camera.
(Either HD/VD input or RS-232C input is selected |
| Power output |
DC12V ± 10%, 800mA max |
| Power consumption |
Less than 5W (without camera) |
| Power input voltage |
AC85V to 132V (usually 100V), 50/60Hz |
| Operating temperature range |
0 to 50ºC (Free from due condensation) |
| Outside dimension |
150 (W) × 43 (H) × 130 (D) mm |
| Weight |
Approx. 600 g |