Output
specification |
|
Models |
Set
type |
NT50 |
NT100 |
NT50P |
NT100P |
| Trns.
type |
NTL50 |
NTL100 |
NTL50P |
NTL100P |
| Rcvr.
type |
NTR50 |
NTR100 |
NTR50P |
NTR100P |
| Detection |
Through
beam |
| Range |
50m |
100m |
50m |
100m |
| Object
resolution |
ø22mm
Max. |
ø28mm
Max. |
ø22mm
Max. |
ø28mm
Max. |
| Power
Supply |
DC12
to 24V ±10%
Ripple 10% Max. |
AC100
to 240V ±10% 50/60Hz |
| Current
consumption/Power consumption |
Trns.:
30mA Max.
Rcvr.: 35mA Max. |
Trns.:
5W Max.
Rcvr.: 5W Max. |
|
Output mode |
NPN
open collector
Sink Current 200mA (DC30V) Max. |
Relay
contact output 1C
MAX 250V 2A (Resistance load) |
| Operation
mode |
Light-ON
Dark-On Switching operation (by switch) |
| Light
monitor |
Output |
NPN
open collector |
Relay
contact output 1C |
| Operation |
 |
| Safety
margin output |
NPN
open collector |
- |
| Response
time |
5ms
Max. |
20ms
Max. |
| Light
source |
Infrared
LED (910nm) |
| Indicators |
Trns.:
P.L: Power (Green LED) … At power-on,
light up
OP.L: Monitor (Red LED) … At emit light
normaly, light up
Rcvr.: OP.L: Operation (Red LED) … At
output-on, light up
LEVEL: Level indicator (Three level display)
LEVEL1: Yellow LED … 2 times
LEVEL2: Yellow LED … 4 times
LEVEL3: Green LED … 8 times
|
| Switch |
Light-ON
Dark-ON |
built-in
SW |
L.ON
side … Output at lighting
D.ON side … Output at light shielding.
|
|
| Materials |
Zinc
dicast |
|
Connection |
Terminal
block type (screw: M3.5, width: 8.1mm) |
| Weight |
Trns.:
700g
Rcvr.: 700g |
Trns.:
800g
Rcvr.: 800g |
Trns.:
700g
Rcvr.: 700g |
Trns.:
800g
Rcvr.: 800g |