4-20mA/24V
Signal & Pulse Signal Use
| MDP-24-1
/ MDP-65-1 |
CE
/ UL |
|
| 4-20
mA & Pulse Signal, Plug-in Type |
| |
| |
MDP-24-1 |
MDP-65-1 |
| Discharge
Voltage |
30V
min. |
70V
min. |
| Max.
Surge Voltage |
45V
max. |
85V
max. |
| Response
Time |
4
nanosec. max. |
| Discharge
Current |
5000A
(8/20 µsec.) |
| Max.
Load Current |
100
mA |
| Internal
Resistance |
20
Ohms (incl. return) |
|
| MDPA-24
/ MDPA-65 |
|
|
| 4-20
mA & Pulse Signal, Plug-in Type, with Life Monitor |
| |
| |
MDPA-24 |
MDPA-65 |
| Discharge
Voltage |
30V
min. |
70V
min. |
| Max.
Surge Voltage |
45V
max. |
85V
max. |
| Response
Time |
4
nanosec. max. |
| Discharge
Current |
5000A
(8/20 µsec.) |
| Max.
Load Current |
100
mA |
| Internal
Resistance |
Approx.
20 Ohms |
|
| MDM2A-24
/ MDM2A-65 |
CE |
|
| 4-20
mA & Pulse Signal, Plug-in Type, with Life Monitor |
| |
| |
MDM2A-24 |
MDM2A-65 |
| Discharge
Voltage |
30V
min. |
70V
min. |
| Max.
Surge Voltage |
45V
max. |
85V
max. |
| Response
Time |
0.1
µsec. max. |
| Discharge
Current |
5000A
(8/20 µsec.) |
| Max.
Load Current |
100
mA |
| Internal
Resistance |
20
ohm(incl. return) |
0.4
ohm max.(incl. return) |
|
| MDK-24 |
|
|
| 4-20
mA & Pulse Signal, DIN rail |
 |
| Discharge
Voltage |
30V
min. |
| Max.
Surge Voltage |
40V
max. |
| Response
Time |
0.1
µsec. max. |
| Discharge
Current |
5000A
(8/20 µsec.) |
| Max.
Load Current |
100
mA |
| Internal
Resistance |
20
Ohms ±5% |
|
| MMDH-24 |
|
|
| 4-20
mA & Pulse Signal, High Speed, High Discharge Current Capacity |
 |
| Discharge
Voltage |
±40V
min. |
| Max.
Surge Voltage |
±50V
max. |
| Response
Time |
4
nanosec. max. |
| Discharge
Current |
20000A
(8/20 µsec.) |
| Max.
Load Current |
0.1
A |
| Internal
Resistance |
0.4
Ohms max. (incl. return) |
|
| MD6T-24
/ MD6T-65 |
|
|
| 4-20
mA & Pulse Signal, Conduit Mount, Weather-Proof |
Terminal Block Connection Type
|
| |
MD6T-24 |
MD6T-65 |
| Discharge
Voltage |
30V
min. |
70V
min. |
| Max.
Surge Voltage |
40V
max. |
100V
max. |
| Response
Time |
4
nanosec. max. |
| Discharge
Current |
10000A
(8/20 µsec.) |
| Max.
Load Current |
100
mA |
| Internal
Resistance |
22
Ohms (incl. return) |
|
| MD6N-24
/ MD6N-65 |
|
|
| 4-20
mA & Pulse Signal, Conduit Mount, Weather-Proof |
Leadwire Connection, Pipe Nipple Type
|
| |
MD6N-24 |
MD6N-65 |
| Discharge
Voltage |
30V
min. |
70V
min. |
| Max.
Surge Voltage |
40V
max. |
100V
max. |
| Response
Time |
4
nanosec. max. |
| Discharge
Current |
10000A
(8/20 µsec.) |
| Max.
Load Current |
100
mA |
| Internal
Resistance |
22
Ohms (incl. return) |
|
| MD6P-24
/ MD6P-65 |
|
|
| 4-20
mA & Pulse Signal, Conduit Mount, Weather-Proof |
Leadwire Connection, Stopping Plug Type
|
| |
MD6P-24 |
MD6P-65 |
| Discharge
Voltage |
30V
min. |
70V
min. |
| Max.
Surge Voltage |
40V
max. |
100V
max. |
| Response
Time |
4
nanosec. max. |
| Discharge
Current |
10000A
(8/20 µsec.) |
| Max.
Load Current |
100
mA |
| Internal
Resistance |
22
Ohms (incl. return) |
|
|