Solution Information & Products
Klemsan

Rails Terminals & Accessories
- AVK Type Rail Terminals
- AVK T Type Rails Terminals
- YBK Type Spring Clamp Terminals
- YBK T Type Earth Terminals
- Double Layer Screw Clamp Terminals
- Multi Layer Screw Clamp Terminals
- 3-4 way Spring Clamp Terminals
- Multi Layer Spring Clamp Terminals
- MVK Type Mini Terminals
- PCY Type Terminals with PCB Connection
- Disconnect and Fuse Terminals
- AVK B Type Busbar Terminals
- Distribution Terminals

Electronic Modules and Accessories


Terminal Blocks
Terminal blocks are components and systems the main function of which is to ensure safe and secure electrical and mechanical conductor connections.The term covers all conceivable types, designs and forms of connection. From the point of view of application, the most important group of terminals is that of rail mounted modular terminal blocks.
  • The current carrying bar must be made of metals, which reduce electrical losses to minimum.
  • Insulation material must be non-flammable and self-extinguishing.
  • The screw must not be loosed due to vibration.
  • The current carrying bar must have such a form that the conductor has a strong contact area in the connection point.
The terminal block series should have a complete range together with all the accessories to provide the best solutions in a minimum area.
 
Materials
KLEMSAN terminals are made of carefully selected standard materials. Insulating materials, clamping metals and conducting metals are subjected to strict quality control as required by stringent international standards.
Clamping yokes and screws are zinc plated which considerably increases the resistance to corrosion. Current bars are made out of brass / electrolytic copper. Coating of tin / lead oxide, nickel while ensuring surface protection guarantees very low contact resistance.
Engineering thermoplastic Polyamide 6.6 has excellent electrical, mechanical and chemical characteristics even at temperatures as high as 100 °C and contains no cadmium based color pigments. Polyamide 6.6 moulded housing absorbs humidity from its surroundings. This makes the plastic material elastic and fracture proof even at temperatures as low as -40 °C. Being a self-extinguishing material it is difficult to ignite and burns only as long as there is a supporting flame. It is rated V2 according to UL94. Good aging resistance and insensitivity to ultraviolet light makes it suitable for tropical and open-air applications.
 
Main Terminology
Modular Terminal Blocks: Modular terminal blocks are used worldwide. Whether they are in distribution boards, control centres or machine control systems, in ship, power stations or railway rolling stock, Klemsan terminals guarantee safe connections in all low voltage installations. In view of this versatile and worldwide application the materials used and the technical data achieved meet the highest quality standard. Approvals have been obtained from all major industrial countries.
Rated Cross-Section: The rated cross-section of a terminal block is a value of conductor cross-section, which is indicated by the manufacturer and covered the thermal, mechanical and electrical requirements.
Rated Current: The rated current of a terminal block is a current value, which is indicated by the manufacturer and covered the thermal, mechanical and electrical requirements on using the rated cross-section.

The Rated Voltage: The rated voltage of a terminal block is a voltage value which is stated by the manufacturer according to creepage and clearance distances and which does not allow any deformation on product.

Nominal Dimensions: Nominal dimensions are the overall dimensions of the terminal block with fixings, but without tolerances. To the specified terminal with a tolerance of +0.2mm. must be allowed during design when mounting in rows.

Insulation Stripping Length: The required stripping length for every Klemsan product is stated in mm. These lengths must be observed.

End Plate: The last terminal in a rail-mounted assembly must be close with an end plate. The end plate is held in position by the end bracket.
Partition: The partition is required for the visual separation of circuits or for electrical separation in case of adjacent cross connections.
Small Partition: Small partitions can be inserted after assembly into terminal blocks of up to a max. thickness of 10mm. between cross connections and test sockets.
 