Progressive Shutter Camera

Progressive Shutter Color Camera

Black and White Video Camera

Color Video Camera

Line Sensor Camera

Power Source Equipment

Monitor

Image Controller & Inspection Equipment
- GS-610
- PC-10J
- OS-20K
- TH-1400
- TH-1400PC
- TP-9854C


OS-20K

Image sensor utilized digital dimension measuring instrument.

Dimentional outline drawing Click here for dimensional outline drawing.
PDF File Click here for the PDF version.
OS-20K

Overview

This dimension measurer (OPTOCIZER) can measure length and width of various substances without direct contact by connecting licenser.
Measuring result is accurate and measuring result is digitally outputted in BCD or binary because measuring is implemented by digital method.
Different output (standard deviation) for center value sheet of set sheet width other than sheet width dimension value are executed.

Features

Setting of upper and lower limit, setting of center value, and input of operation check function is interactively implemented using numerical keypad switch.
Measuring range can be changed freely.
Light resource dust cancel can be executed.
Failure diagnoses function is provided.

Contents of operation

Measuring example of sheet width
All width of on line sheet is measured by optically and width dimension is outputted.
Misaligned width (deviation value) against center value of previously set sheet width is outputted.
Error value signal is issued when other than specified width are measured concerning upper and lower limit value.
Sheet width value and deviation value are issued both analogue and digital output.
Synchronizing signal to determine starting and termination of measurement can be executed only inputting of contact signal such as relay.
Measured dimension value and deviation value are outputted through connector for external numeral display.
Setting and output value, etc. mentioned above can be connected to RS-232C and computer. (Optional)
Measure value and setting value are displayed on liquid crystal panel.

Specifications

Item/mode Dimension measurement or center measuring
2 units
Photo receiver 1 unit 2 units
Slice level
0.0 to 9.9 V (binarization)
Scanning frequency
1 to 10 m sec
Average times 1 , 2 , 4 , 8 , 16
Visual field setting 0 to 599.99 mm
0 to 999.9 mm (CH1, 2 each setting)
Standard width setting 0 to 599.99 mm
0 to 999.9 mm
0 to 999.99 mm
0 to 4999.9 mm
Center position reference setting ±0 to 299.99 mm
±0 to 499.9 mm
Photo receiver - 0 to 399.99mm
0 to 3999.9mm
Upper limit 0 to 99.99mm
0 to 99.9mm
Lower limit 0 to 99.99mm
0 to 99.9mm
Mask width (start) 0 to 599.99 mm
(Visual field setting ≥ mask width (start) + mask width (end))
0 to 999.9 mm Note2
Mask width (end) 0 to 599.99 mm
(Visual field setting ≥ mask width (start) + mask width (end))
0 to 999.9 mm Note2
Analogue out
(Power output)
Setting 1
4 to 20mA@
Dimension 0 to 599.99 mm
0 to 999.9 mm
0 to 599.99 mm
0 to 999.9 mm
Deviation ±0 to 599.99 mm
±0 to 999.9 mm
±0 to 599.99 mm
±0 to 999.9 mm
Analogue output
(Power output)
Setting 1
4 to 20mA
Dimension 0 to 599.99 mm
0 to 999.9 mm
0 to 599.99 mm
0 to 999.9 mm
Deviation ±0 to 599.99 mm
±0 to 999.9 mm
±0 to 599.99 mm
±0 to 999.9 mm
External output
(DATA OUT)
Dimension/deviation (dimension, center) / off
Binary /BCD
Synchronous input selection INT/EXT, STEP/EXT, CONT
Operation power source Voltage AC85V to 130V
Frequency 47HZ to 440HZ
Power consumption 80VA
General purpose Connection method Terminal block 20P
Ambient temperature 10ºC to 40ºC
Ambient humidity 30 to 90 % RH (Free from due condensation)
Outside dimension 370 (W) × 150 (H) × 330 (D)
Weight Approx. 6 kg
Note1:
Setting of digital number is set either 1 or 2 digits after the decimal point. Setting range mentioned above upper is set to 2 digits and lower is set to 1 digit.
Note2:
Concerning mask width setting is a little different. (Mask is processed in 8 bit unit.)