50
mA Output |
|
- Specific input within ±300
V; current input with a resistor
- Non-isolated 10-50 mAdc output
- 100, 110, 120, 200, 220, 240
Vac powered
Applications:
Interfacing between 10-50 mA and 4-20 mA systems |
| SVA |
CE |
|
|
|
200
mA Output |
|
- Specific input within ±300
V; current input with a resistor
- Isolated 10-50 mA, 0-50 mA, 0-100
mA, 0-200 mA, 0-20 Vdc output
- 100-120 V, 200-240 Vac or 110
Vdc powered
Applications:
Retrofitting 10-50 mAdc control system; DC excitation
for an electromagnetic coil which demands a high
power; Driving actuators used in turbines, speed
governors, and vari-axial fan control actuators;
Valve positioners/actuators utilized in hydraulic
equipment requiring 0-200 mAdc signal conversion
from a standard DC signal level |
| 99SVA |
|
|
|
|
1
A Output |
|
- Specific input within ±300
V; current input with an internal resistor
- Isolated 0-1 Adc output
- 85-264 Vac powered
- 50% zero & span adjustments
- Low heat emission design (12W
with maximum load)
Applications:
Driving hydraulic machinery; Remote setting for
testing equipment |
| CVRTD
|
|
|
|
|
RTD
Output
|
|
- Emulates the RTD resistance proportional
to a DC signal
- 4-20 mA or 1-5 Vdc input
- Pt 100 equivalent resistance
output
- 100, 110, 115, 120, 200, 220,
240 Vac or 12, 24, 48 Vdc powered
- Response time 0.5 seconds or
less
- Output drive circuit with semiconductor
switches ensures long life span
- Fixed output at power failure
Applications:
Controlling an RTD input device with a DC signal
|
| CVR1 |
|
|
|
Potentiometer
Output |
|
- 0-10 V, 0-1 V, 0-5 V, 1-5 Vdc
input; current input with a resistor
- 135, 1k, 100, 200, 500, 2k, 5k,
10k, 20k, 50k, 100k ohms output
- 85-132 Vac powered
- Permissible wattage 1W
Applications:
Remote setting for inverters; Remote setting for
Honeywell’s Modutrol motors; Remote setting
for various instruments with potentiometer settings |
| MXS |
|
|
|
Self-synch
Input
|
|
- Converts position signal from
a self-synchronizing motor into a DC signal proportional
to the rotating shaft position .
- Input range selectable within
0-360 degrees
- Output selectable within 0-20
mA and +/-10 V.
- 85-132 V or 170-264 Vac powered
- Linearization
- Loop test output
Applications:
Position indicator using self-synch for valves and
gates; Tank gauge; Sounding level meter |
| MNV |
|
|
|
Analog
Switching Module |
|
- Selects one signal as output
from up to four analog input signals
- Distributes a single input signal
to any or all of the up to four output channels
- ±10 Vdc input, minimum
span 10mV, 50 mA max.
- 100, 110, 115, 120, 200, 220,
240 Vac or 12, 24, 48 Vdc powered
Applications:
Switching 1 – 5V DC signal without worrying
about contact failures that happen when using mechanical
contacts for this purpose; Switching low-speed pulse
signals; Switching alternating signals |
MFS
|
|
|
|
Split-Range
Transmitter |
|
- Generates two signals which control
two final control elements
- V-shape and parallel output characteristics
- 4-20 mA input
- 12-20 mA and 4-12 mA (inverted
with V-shape) outputs
- 100, 110, 115, 120, 200, 220,
240 Vac or 24 Vdc powered
Applications:
Balancing two final control elements in opposite
actions used in heating-cooling or humidifying-dehumidifying
processes
|
MXMS
|
CE |
|
|
Programmed
Ramp Generator |
|
- Generates various patterns of
output by front UP-DOWN key programming
- Max. 16-point-segment ramps can
be generated
- Output selectable within 0-20
mA and +/-10 V.
- 100-240 Vac, 12-24 Vdc, or 110
Vdc powered
- Loop test output
Applications:
Parameters setting for computers and DCS; Signals
used in a panel, which are rarely changed. |
AD3V
|
CE |
|
|
16-bit
Parallel Digital Output |
|
- BCD, binary, reflected binary,
two's complement outputs selectable
- Open collector or CMOS for output
levels
- Output can be scaled and displayed
in convenient engineering unit
- 100-240 Vac, 12-24 Vdc, or 110
Vdc powered
- Loop test output
- Response time adjustable within
0.15 and 60 sec.
Applications:
Interface of analog signal to computers and PLC;
Input to a digital panel meter |
DA3
|
CE |
|
|
16-bit
Parallel Digital Input |
|
- BCD, binary, offset binary, two's
complement, reflected binary inputs
- Positive or negative logic selectable
- Display can be scaled in convenient
engineering unit
- 100-240 Vac, 12-24 Vdc, or 110
Vdc powered
Applications:
Interface of analog signal for computers and PLC |
|
|