Sensor Signal Use
| MDP-TC |
|
|
| Thermocouples
Use |
| |
| Discharge
Voltage |
7.5V min. |
| Max.
Surge Voltage |
16V max. |
| Response
Time |
0.1 µsec.
max. |
| Discharge
Current |
5000A (8/20
µsec.) |
| Max.
Load Current |
100 mA |
| Internal
Resistance |
approx.
20 Ohms(incl. return) |
|
MDP-RB
|
CE |
|
| RTD Use |
| |
| Discharge
Voltage |
±3V
min. |
| Max.
Surge Voltage |
±16V
max. |
| Response
Time |
0.1 µsec.
max. |
| Discharge
Current |
5000A (8/20
µsec.) |
| Max.
Load Current |
100 mA |
| Internal
Resistance |
10 ohms
±0.1% (3-wire) |
|
| MDP-PM |
|
|
| Potentiometers
Use |
| |
| Discharge
Voltage |
7.5V min. |
| Max.
Surge Voltage |
16V max. |
| Response
Time |
0.1 µsec.
max. |
| Discharge
Current |
5000A (8/20
µsec.) |
| Max.
Load Current |
100 mA |
| Internal
Resistance |
10 Ohms
±0.1% (3-wire) |
|
| MDP-LC |
|
|
| Strain
Gauge Use, Plug-in Type |
| |
Discharge
Voltage |
Line
Side |
±0.3V
min. |
Exc.
Side |
15V
min. |
Max.
Surge Voltage |
Line
Side |
±15V
max. |
Exc.
Side |
30V
max. |
Response
Time |
5
nsec. max. |
Discharge
Current |
Line
Side |
100A
(8/20 µsec.) |
| Exc.
Side |
50A
(8/20 µsec.) |
|
| MDK-LC |
|
|
| Strain
Gauge Use, DIN rail |
 |
Discharge
Voltage |
Line
Side |
±0.3V
min. |
Exc.
Side |
15V
min. |
Max.
Surge Voltage |
Line
Side |
±15V
max. |
Exc.
Side |
30V
max. |
Response
Time |
5
nsec. max. |
Discharge
Current |
Line
Side |
100A
(8/20 µsec.) |
| Exc.
Side |
50A
(8/20 µsec.) |
|
| MDK-LV |
|
|
| Signal
Line with Exc. Use |
| |
Discharge
Voltage |
Line
Side |
10V
min. |
Exc.
Side |
30V
min. |
Max.
Surge Voltage |
Line
Side |
20V
max. |
Exc.
Side |
40V
max. |
Response
Time |
0.1
µsec. max. |
Discharge
Current |
Line
Side |
5000A
(8/20 µsec.) |
| Exc.
Side |
|
| MDP-JS |
|
|
| Self-Synch
Use, Plug-in Type |
| |
| Discharge
Voltage |
±170V
min. (peak-to-peak) |
| Max.
Surge Voltage |
±350V
max. (peak-to-peak) |
| Response
Time |
0.1 µsec.
max. |
| Discharge
Current |
5000A (8/20
µsec.) |
| Max.
Load Current |
500 mA |
| Internal
Resistance |
approx.
2 ohms per wire |
|
| MDP-SP |
|
|
| Low
Frequency Pulse Use |
| |
| Discharge
Voltage |
14V min. |
| Max.
Surge Voltage |
30V max. |
| Response
Time |
0.1 µsec.
max. |
| Discharge
Current |
5000A (8/20
µsec.) |
| Max.
Load Current |
50 mA |
| Internal
Resistance |
10 ohms
±0.1% |
|
| MDR-8 |
|
|
| 8-point
On-Off Signal, Terminal Board Type |
| |
| Discharge
Voltage |
30V min. |
| Max.
Surge Voltage |
40V max. |
| Response
Time |
0.1 µsec.
max. |
| Discharge
Current |
1000A (8/20
µsec.) |
| Max.
Load Current |
100 mA |
| Internal
Resistance |
approx.
10 ohms |
|
|
|