| Temperature |
|
| PC
Programming & "One-Step Cal" Universal I/O |
- DC mV, V & mA,
T/C, RTD, Pot and resistance input
- Output selectable
within 0-20 mA and ±10 V
- 100-240 Vac or 24
Vdc powered
- DIP switch or PC configuration
- 128-point linearization
(DC input) using the PC Configurator (1000 points for T/C, 500
points for RTD)
|
|
| PC
& "One-Step Cal" Programmable I/O |
- K, E, J, T, B, R,
S, C, N, U, L, PL-II selectable
- Output selectable
within 0-20 mA and ±10 V
- 10-32 Vdc powered
- DIP switch or PC configuration
- 300-point linearization
using the PC Configurator
|
|
| PC
Programmable, Plug-in Socket Mounted |
- DC mV, V & mA,
T/C, RTD and Pot input.
- Output selectable
within 0-20 mA and ±10 V.
- 100-240 Vac or 24
Vdc powered
- 100-point linearization
- UL/cUL Class I, Div.
2 approval
|
| |
| PC
Programmable Universal Input with Modbus RTU |
- DC mV, V & mA,
T/C, RTD and Pot input.
- Output selectable
within 0-20 mA and ±10 V.
- RS-485/Modbus RTU,
38.4 kbps
- 100-240 Vac or 24
Vdc powered
- 100-point linearization
|
|
| PC
Programmable T/C Input |
- K, E, J, T, B, R,
S, C, N, U, L, PL-II selectable
- Output selectable
within 0-20 mA and +/-10 V.
- 100-240 Vac or 24
Vdc powered
- UL/cUL Class I, Div.
2 approval
|
|
| PC
Programmable RTD Input |
- Pt100, Pt1000, Pt50,
Ni100, Ni508.4, Cu10 selectable.
- Output selectable
within 0-20 mA and +/-10 V.
- 100-240 Vac or 24
Vdc powered
- UL/cUL Class I, Div.
2 approval
|
|
| Fixed
Range RTD Input, Super-Slim Type |
- Specify Pt100, Pt50,
Ni508.4 and temp. range. Special RTD acceptable.
- 100-240 Vac / 24 Vdc
universal power input
- Fast response 25 msec.
optional
|
|
| Fixed
Range T/C Input |
- Specify K, E, J, T,
B, R, S, N and temp. range. Special T/C acceptable.
- 100-240 Vac or 24
Vdc powered
- Fast response 25 msec.
optional
- UL/cUL Class I, Div.
2 approval
|
| |
| Fixed
Range T/C Input Signal Splitter |
- Specify K, E, J, T,
B, R, S, N and temp. range. Special T/C acceptable.
- Independent current/voltage
output ranges can be specified.
- 100-240 Vac or 24
Vdc powered
- Fast response 25 msec.
optional
- UL/cUL Class I, Div.
2 approval
|
|
| Fixed
Range RTD Input |
- Specify Pt100, Pt50,
Ni508.4 and temp. range. Special RTD acceptable.
- 100-240 Vac or 24
Vdc powered
- Fast response 25 msec.
optional
- UL/cUL Class I, Div.
2 approval
|
|
| Fixed
Range RTD Input Signal Splitter |
- Specify Pt100, Pt50,
Ni508.4 and temp. range. Special RTD acceptable.
- Independent current/voltage
output ranges can be specified.
- 100-240 Vac or 24
Vdc powered
- Fast response 25 msec.
optional
- UL/cUL Class I, Div.
2 approval
|
|
| Fixed
Range T/C Input, Low Cost |
- Specify K, E, J, T,
B, R, S, N and temp. range. Special T/C acceptable.
- 100-240 Vac or 24
Vdc powered (CE for 24 Vdc type)
- Fast response 25 msec.
optional
|
| |
| Fixed
Range RTD Input, Low Cost |
- Specify Pt100, Pt50,
Ni508.4 and temp. range. Special RTD acceptable.
- 100-240 Vac or 24
Vdc powered (CE for 24 Vdc type)
- Fast response 25 msec.
optional
|
|
| Fixed
Range T/C Input Signal Splitter, Low Cost |
- Specify K, E, J, T,
B, R, S, N and temp. range. Special T/C acceptable.
- Independent output
ranges selectable
- CE marking for 24
Vdc powered
- Fast response 25 msec.
optional
|
|
| Fixed
Range RTD Input Signal Splitter, Low Cost |
- Specify Pt100, Pt50,
Ni508.4 and temp. range. Special RTD acceptable.
- Independent output
ranges selectable
- CE marking for 24
Vdc powered
- Fast response 25 msec.
optional
|
|
| Universal
Temperature Input, HART Programmable |
- mV, V, T/C, RTD, resistance
and potentiometer input
- 12-42 Vdc powered
|
| |
| Universal
Temperature Input, PROFIBUS-PA |
- mV, V, T/C, RTD, resistance
and potentiometer input
- 9-30 Vdc powered
|
|
| Output
Loop Powered, DIP Switch Configurable T/C Input |
- K, J, T or E, R, N
selectable
- 12-45 Vdc powered
|
|
| Output
Loop Powered, DIP Switch Configurable RTD Input |
- Pt100, Ni120, Cu10
selectable
- 12-45 Vdc powered
|
|
| Universal
Temperature Input, HART Programmable, I/S |
- DC mV, V & mA,
T/C, RTD, Pot and resistance input.
- 12-42 Vdc powered
(max. 28 V approved)
- ATEX Zone 0 approval
- FM Class I, Div. 1
& 2 approval
|
| |
| Universal
Temperature Input, HART Programmable, Explosion-proof |
- DC mV, V & mA,
T/C, RTD, Pot and resistance input.
- 12-42 Vdc powered
(max. 28 V approved)
- NEMA 4X, IP65 enclosure
- ATEX Zone 0 approval
- FM Class I, II, III,
Div. 1 & Class I, II, Div. 2 approval
|
|
| Universal
Temperature Input, HART Programmable |
- DC mV, V & mA,
T/C, RTD, Pot and resistance input.
- 8-35 Vdc powered
- ATEX approval pending
- FM approval pending
|
|
| Output
Loop Powered, Fixed Range T/C Input |
- Specify K, E, J, T,
B, R, S, N and temp. range. Special T/C acceptable.
- 12-32 Vdc powered
- Fast response 25 msec.
optional
|
| |
| Output
Loop Powered, Fixed Range RTD Input, Isolated |
- Specify Pt100, Pt50,
Ni 508.4 and temp. range.
- 12-32 Vdc powered
- Fast response 25 msec.
optional
|
|
| Output
Loop Powered, Fixed Range RTD Input |
- Pt100 input. Select
temp. range. Non-isolated.
- 8.5-32 Vdc powered
- Economical model
|
|
| Output
Loop Powered, Fixed Range RTD Input, Intrinsically Safe |
- Pt100 input. Select
temp. range. Non-isolated.
- 12-30 Vdc powered.
- ATEX Zone 0 approval
|
|
| Output
Loop Powered, Fixed Range T/C Input, Low Cost |
- Specify K, E, J, T,
B, R, S, N and temp. range. Special T/C acceptable.
- 12-28 Vdc powered
- Fast response 25 msec.
optional
|
| |
| Output
Loop Powered, Fixed Range RTD Input, Low Cost |
- Specify Pt100, Pt50,
Ni508.4 and temp. range. Special RTD acceptable.
- 12-28 Vdc powered
- Fast response 25 msec.
optional
|
|