I/O - R3 Series



Features

  • Great flexibilities in number and type of I/O signals: DC current/voltage, temperature, strain gauge, AC current/voltage, AC power, etc.
  • Economical DC input module can handle fully-isolated 4 points up to non-isolated 16 points.
  • Hot-swappable I/O modules
  • Dual redundant communication networks
    
M3 screw terminal block is used for I/O modules. The removable terminal block is convenient for maintenance. Network Module and Power Supply Module in one housing. One I/O module plus one Network Module with power supply is the minimum unit: Space-saving and economical solution.
Horizontal mount base can be used just like the relaying terminal board in an instrumentation panel.
Dual network communication modules are optional for mission critical applications.
If you choose two different network protocols for the network modules, the remote I/Os can be directly monitored by two different                                                                                                                      manufacturers’ PLC systems.
The Power Supply Module is located at the right end, with Network Module inserted at its left. Network Module with incorporated power supply is available for small systems.
Multiple I/O modules can be mounted; No.1 at the extreme left end, No.2 and following modules to its right.
POWER MODULES
Model
Rating
R3-PS1 20V 750mA
R3-PS2 20V 1.5A (double width)

BASE
Model
Network
R3-BS 2...16 Positions
R3-BSW 4...16 Positions,
free I/O address
NETWORK MODULES
Model
Capacity
R3-NE1 Modbus/TCP (Ethernet)
R3-NM1 Modbus
R3-ND1
DeviceNet
Analog 16 ch.
R3-ND2 Analog 32 ch.
R3-ND3 Analog 64 ch.
R3-NP1 PROFIBUS-DP
R3-NC1
CC-Link
Ver. 1; Analog 16 ch.
R3-NC2 Ver. 1; Analog 32 ch.
R3-NC3 Ver. 2
R3-NL1 LONWORKS
R3-NF1 T-Link
ANALOG INPUT MODULES
Input
Model
CH
Specifications
Thermocouple
R3-TS4 4 (isolated)
Input: K, E, J, T, B, R, S, C, N, U, L, P
Accuracy: ±1.0°C
Conversion Rate: 250 ms or 1 s
R3-TS8 8 (isolated)
RTD
R3-RS4 4 (isolated) Input: Pt100, Pt1000*, Pt50, Ni100, Ni1000*, Ni508.4*, Cu10, Cu50 (* R3-RS4 only)
Accuracy: ±1.0°C
Conversion Rate: 250 ms or 1 s
R3-RS8 8 (isolated)
DC Voltage
R3-SV4 4 (isolated) Input: ±10V, ±5V, ±1V, 0–10V, 0–5V, 1–5V, 0–1V
R3-SV8 8 (isolated)
R3-SV8N 8 (non-isolated) Future Plan
R3-SV16N 16 (non-isolated) Input: ±10V, ±5V, 0–10V, 0–5V, 1–5V
DC Millivolt
R3-SV4A 4 (isolated) Input: ±100mV, ±50mV, 0–100mV, 0–60mV, 0–50mV
R3-SV8A 8 (isolated)
DC Current
R3-SS4 4 (isolated) Input: ±20mA, 0–20mA, 4–20mA
Input Resistance: 250O
R3-SS8 8 (isolated) Input: ±20mA, 0–20mA, 4–20mA
Input Resistance: 20O
R3-SS8N 8 (non-isolated) Input: 4–20mA
Input Resistance: 250O
R3-SS16N 16 (non-isolated) Input: ±20mA, 0–20mA, 4–20mA
Input Resistance: 56O
4-20mA
with Excitation
R3-DS4 4 (isolated) Input: 4-20mA
Supply Output: 24–28V (Max. 22mA)
R3-DS8N 8 (non-isolated) Input: 4-20mA
Supply Output: 24V (Min. 300mA)
Potentiometer
R3-MS4 4 (isolated) Input: 100O to 20kO
R3-MS8 8 (isolated) Input: 500O to 100kO
CT
R3-CT4 4 (isolated) Input: 0–5Aac, 0–1Aac (RMS sensing)
PT
R3-PT4 4 (isolated) Input: 0–250Vac, 0–50Vac
Watt
R3-WT4 4 (isolated) System configuration: 3-phase/3-wire, single-phase/2- or 3-wire
Input: 110Vac or 220Vac, 1A or 5A
Totalized Pulse
R3-PA4 4 (isolated) Future Plan
R3-PA16 16 (isolated) Input: Dry contact
Sensing: Max. 24V (internal or external)
Max. Frequency: 100Hz
Totalized count: 1 to 10000

ANALOG OUTPUT MODULES
Output
Model
CH
Specifications
DC Voltage
R3-YV4 4 (isolated) Output: ±10V, ±5V, ±1V, 0–10V, 0–5V, 1–5V, 0–1V
Accuracy: ±0.05% (±0.1% for R3-YV8)
Response Time: Max. 0.2 s (0–90%)
R3-YV8 8 (isolated)
DC Current
R3-YS4 4 (isolated) Output: 4–20mA
Accuracy: ±0.1%
Response Time: Max. 0.2 s (0–90%)
Pulse
R3-PC16A 16 Input: Open collector
Rated Load: 24Vdc
Max. Frequency: 100Hz
Totalized count: 1 to 10000

DISCRETE MODULES
I/O
Model
CH
Specifications
16-point Dry Contact Input R3-DA16
16
Input: Dry contact
Sensing: 24Vdc
(external exc. for R3-DA16A)
16-point Contact Input with External Exc. R3-DA16A
16
16-point AC Contact Input R3-DA16B
16
Input: 100-240Vac
32-point Dry Contact Input R3-DA32A
32
Input: Dry contact
Ext. excitatlion: 24Vdc
64-point Dry Contact Input R3-DA64A
64
16-point Relay Output R3-DC16
16
Output: Relay contact
Rated Load: 250Vac/30Vdc 0.5A
16-point Open Collector Output R3-DC16A
16
Output: Open collector
Rated Load: 24Vdc
32-point Open Collector Output R3-DC32A
32
64-point Open Collector Output R3-DC64A
64
16-point Triac Output R3-DC16B
16
Output: Triac
Rated Load: 100-240Vac

 

 