M-System Products

Alarm

I/O

Surge Protector

Signal

Transducer

Trend & Log

Download
- Signal
- Alarm
- Transducer

Application

Downloads

Temperature |
AC |

Temperature
M3LU
CE   
PC Programming & "One-Step Cal" Universal I/O
  • DC mV, V & mA, T/C, RTD, Pot and resistance input
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
  • DIP switch or PC configuration
  • 128-point linearization (DC input) using the PC Configurator (1000 points for T/C, 500 points for RTD)
M3LT
CE   
PC & "One-Step Cal" Programmable I/O
  • K, E, J, T, B, R, S, C, N, U, L, PL-II selectable
  • Output selectable within 0-20 mA and ±10 V
  • 10-32 Vdc powered
  • DIP switch or PC configuration
  • 300-point linearization using the PC Configurator

M2XU
CE / UL / cUL   
PC Programmable, Plug-in Socket Mounted
  • DC mV, V & mA, T/C, RTD and Pot input.
  • Output selectable within 0-20 mA and ±10 V.
  • 100-240 Vac or 24 Vdc powered
  • 100-point linearization
  • UL/cUL Class I, Div. 2 approval
M2XUM
CE   
PC Programmable Universal Input with Modbus RTU
  • DC mV, V & mA, T/C, RTD and Pot input.
  • Output selectable within 0-20 mA and ±10 V.
  • RS-485/Modbus RTU, 38.4 kbps
  • 100-240 Vac or 24 Vdc powered
  • 100-point linearization
M2XT
CE / UL / cUL   
PC Programmable T/C Input
  • K, E, J, T, B, R, S, C, N, U, L, PL-II selectable
  • Output selectable within 0-20 mA and +/-10 V.
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
M2XR
CE / UL / cUL   
PC Programmable RTD Input
  • Pt100, Pt1000, Pt50, Ni100, Ni508.4, Cu10 selectable.
  • Output selectable within 0-20 mA and +/-10 V.
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval

M3SRS
CE    
Fixed Range RTD Input, Super-Slim Type
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • 100-240 Vac / 24 Vdc universal power input
  • Fast response 25 msec. optional

M2TS
CE / UL / cUL   
Fixed Range T/C Input
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
W2TS
CE / UL / cUL   
Fixed Range T/C Input Signal Splitter
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • Independent current/voltage output ranges can be specified.
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
M2RS
CE / UL / cUL   
Fixed Range RTD Input
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
W2RS
CE / UL / cUL   
Fixed Range RTD Input Signal Splitter
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • Independent current/voltage output ranges can be specified.
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval

M5TS
CE    
Fixed Range T/C Input, Low Cost
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
  • Fast response 25 msec. optional
M5RS
CE    
Fixed Range RTD Input, Low Cost
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
  • Fast response 25 msec. optional
W5TS
CE    
Fixed Range T/C Input Signal Splitter, Low Cost
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • Independent output ranges selectable
  • CE marking for 24 Vdc powered
  • Fast response 25 msec. optional
W5RS
CE    
Fixed Range RTD Input Signal Splitter, Low Cost
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • Independent output ranges selectable
  • CE marking for 24 Vdc powered
  • Fast response 25 msec. optional

B3HU
CE    
Universal Temperature Input, HART Programmable
  • mV, V, T/C, RTD, resistance and potentiometer input
  • 12-42 Vdc powered
B3PU
CE    
Universal Temperature Input, PROFIBUS-PA
  • mV, V, T/C, RTD, resistance and potentiometer input
  • 9-30 Vdc powered
B3FT
CE    
Output Loop Powered, DIP Switch Configurable T/C Input
  • K, J, T or E, R, N selectable
  • 12-45 Vdc powered
B3FR
CE    
Output Loop Powered, DIP Switch Configurable RTD Input
  • Pt100, Ni120, Cu10 selectable
  • 12-45 Vdc powered

B6U
CE / ATEX / FM   
Universal Temperature Input, HART Programmable, I/S
  • DC mV, V & mA, T/C, RTD, Pot and resistance input.
  • 12-42 Vdc powered (max. 28 V approved)
  • ATEX Zone 0 approval
  • FM Class I, Div. 1 & 2 approval
B6U-B
CE / ATEX / FM   
Universal Temperature Input, HART Programmable, Explosion-proof
  • DC mV, V & mA, T/C, RTD, Pot and resistance input.
  • 12-42 Vdc powered (max. 28 V approved)
  • NEMA 4X, IP65 enclosure
  • ATEX Zone 0 approval
  • FM Class I, II, III, Div. 1 & Class I, II, Div. 2 approval

27HU
CE    
Universal Temperature Input, HART Programmable
  • DC mV, V & mA, T/C, RTD, Pot and resistance input.
  • 8-35 Vdc powered
  • ATEX approval pending
  • FM approval pending

26TS1
CE    
Output Loop Powered, Fixed Range T/C Input
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • 12-32 Vdc powered
  • Fast response 25 msec. optional
26RS
CE    
Output Loop Powered, Fixed Range RTD Input, Isolated
  • Specify Pt100, Pt50, Ni 508.4 and temp. range.
  • 12-32 Vdc powered
  • Fast response 25 msec. optional
26R1
CE    
Output Loop Powered, Fixed Range RTD Input
  • Pt100 input. Select temp. range. Non-isolated.
  • 8.5-32 Vdc powered
  • Economical model
26REX
CE / ATEX   
Output Loop Powered, Fixed Range RTD Input, Intrinsically Safe
  • Pt100 input. Select temp. range. Non-isolated.
  • 12-30 Vdc powered.
  • ATEX Zone 0 approval

B5TS
CE    
Output Loop Powered, Fixed Range T/C Input, Low Cost
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • 12-28 Vdc powered
  • Fast response 25 msec. optional
B5RS
CE   
Output Loop Powered, Fixed Range RTD Input, Low Cost
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • 12-28 Vdc powered
  • Fast response 25 msec. optional
home | about us | contact | sitemap

Copyright © Alstron (Singapore) Pte Ltd 2013