M-System Products

Alarm

I/O

Surge Protector

Signal

Transducer

Trend & Log

Download
- Signal
- Alarm
- Transducer

Application

Downloads

Pulse |
AC |
 
Pulse
M3LPA
CE   
PC & "One-Step Cal" Programmable Frequency Input
  • Open collector, dry contact, voltage pulse, two-wire current, RS-422 line driver selectable; 0-100 kHz max.
  • Excitation 4 V, 8 V or 12 V selectable
  • Output selectable within 0-20 mA and +/-10 V.
  • 100-240 Vac or 24 Vdc powered
  • DIP switch or PC configuration
  • 101-point linearization using the PC Configurator

M2XPA2
CE    
PC Programmable Frequency Input
  • Open collector, mechanical contact, voltage pulse, two-wire current, RS-422 line driver selectable; 0-100 kHz max.
  • Excitation 4 V, 8 V or 12 V selectable
  • Output selectable within 0-20 mA and +/-10 V.
  • 100-240 Vac or 24 Vdc powered

M2SP
CE / UL / cUL   
Fixed Range Frequency Input
  • Dry contact or voltage pulse. Specific input range up to 10 kHz
  • Excitation 12 V @30 mA
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
W2SP
CE / UL / cUL   
Fixed Range Frequency Input Signal Splitter
  • Dry contact or voltage pulse. Specific input range up to 10 kHz
  • Excitation 12 V @30 mA
  • Independent current/voltage output ranges can be specified.
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
M2AP
CE / UL / cUL   
Fixed Range Frequency Output
  • Specific input range up to 300 V
  • Open collector, 5V pulse or mercury relay output. Specific output range up to 1 kHz
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
W2AP
CE / UL / cUL   
Fixed Range Frequency Output Signal Splitter
  • Specific input range up to 300 V
  • Open collector, 5V pulse or mercury relay output. Specific output range up to 10 kHz
  • 100-240 Vac or 24 Vdc powered.
  • UL/cUL Class I, Div. 2 approval
M2PP
CE / UL   
Pulse Isolator
  • Mechanical contact, open collector or voltage pulse input; 0-10 kHz max.
  • Open collector, voltage pulse or mercury relay output
  • 100-240 Vac or 24 Vdc powered.
  • UL Class I, Div. 2 approval
M2PRU
CE    
Pulse Scaler
  • Open collector, mechanical contact, 5V pulse or two-wire current pulse input; 0-100 kHz max.
  • Excitation 12 V/24 V @30mA
  • Open collector, voltage pulse, AC/DC switch output
  • Scaling factor adjustable of 1.000 x 1/1 to 0.0001 x 1/1000000
  • 100-240 Vac or 24 Vdc powered

M5PA
CE    
Fixed Range, Low Cost
  • Open collector, mechanical contact, 5V/12V/24V pulse. Specific input range up to 100 kHz
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)

B3FP
CE    
Output Loop Powered, DIP Switch Configurable Input
  • Input type and frequency range selectable
  • 12-45 Vdc powered

YPD
CE    
Pulse Isolator
  • Dry contact, voltage pulse or two-wire current input; 0-100 kHz max.
  • Excitation 5 V or 12 V
  • Open collector, voltage pulse or relay contact output
  • 100, 110, 115, 120, 200, 220, 240 Vac or 12, 24, 48 Vdc powered
WYPD
CE    
Pulse Signal Splitter
  • Dry contact, voltage pulse or two-wire current input; 0-100 kHz max.
  • Excitation 5 V or 12 V
  • Open collector, voltage pulse or relay contact output (two)
  • 100, 110, 115, 120, 200, 220, 240 Vac or 12, 24, 48 Vdc powered

JRP2
   
Rotary Encoder Speed Input
  • Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse speed signal
  • Open collector, voltage pulse or RS-422 line driver pulse inputs
  • Excitation 5 V, 12 V or 24 V
  • 85-132 Vac or 12, 24, 48, 110 Vdc powered

Applications: Measuring moving speed of a machine with a rotary encoder

JRQ2
   
Rotary Encoder Position Input
  • Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse position signal
  • Open collector, voltage pulse or RS-422 line driver pulse inputs
  • Excitation 5 V, 12 V or 24 V
  • 85-132 Vac or 12, 24, 48, 110 Vdc powered

Applications: Measuring moving distance of a machine with a rotary encoder

RPPD
   
Rotary Encoder Pulse Isolator
  • Galvanically isolates two pulse rate signals from a rotary encoder
  • Dry contact, voltage pulse, two-wire current pulse, or RS-422 line driver pulse inputs
  • Relay, open collector or voltage pulse outputs
  • Excitation 5 V, 12 V or 24 V
  • 85-132 Vac or 12, 24, 48, 110 Vdc powered

Applications: Isolating field pulse signals in order to reduce noise interference

home | about us | contact | sitemap