XTOP 10 Series, XTOP12TS and XTOP15TX
|
|
| |
|
|
|
*Click To View Larger*
|
|
Model
|
Front |
Side |
Rear |
| F1 |
F2 |
S1 |
S2 |
S3 |
R1 |
R2 |
| XTOP15TX |
366 |
296.5 |
58 |
283.5 |
51 |
352.8 |
283.8 |
| XTOP12TS |
317 |
257 |
58 |
244.3 |
51 |
303.8 |
244.3 |
| XTOP10TV/10TS |
305 |
239 |
58 |
226.4 |
51 |
292.4 |
226.4 |
65,536 Color & Analog Touch
>High Color TFT LCD & STN LCD
|
Adopt Analog Touch Screen
>Compared with existing matrix
touch screen,it has no scale marks
in it's face, so it is clean.
>Designing is possible, free from
restriction of grid. So that the
user can conveniently arrange
objects on the screen.
|
Multi Language Table
>Design for conversion of
language in string table.
-A string table, which makes it
impossible to simply set a language
for each country, is available so while working,
User can change the previously designed language
in the same table by using the
programming function.
|
Extended Alarm Functions
>Easy Indication to be easy
understanding for operator
-Various editor key options to control
contents in alarm list
-Display in time and reverse time order on
events like ocurrence/clearance/acknowledge of alarm
-Setting of alarm and subsidiary explanation
:shift screen/display subsidiary explanation
by using ex-tag
-Display alarms stored in CF card
|
Windows Font
>Support Various Fonts
-Make various size fonts and font style
using the MS Windows Font on the PC
|
Various graphic library availble
>Adopt graphic images which are often
used at sites. Classification by object is easy
so it can be used for various product group. Also
support high quality vector library make user
interface more conveniently.
|
Security Setting
>Security settings for each screen
Making authority of setting & access to the screen
to who have access rights
-Set up password & Security level for each screen
-Password tenkey to input password like default tenkey
-Max. 16 levels of security settings and initialization of levels
|
TOP Analyzer
>Analyzer communication problems, which happen on sites,
with the analyzer function of X TOP. That is possible
to save communication details between XTOP
and PLC in a file, using the TOP Analyzer function.
By analyzing them, it is possible to easily
solve communication problems.
|
Recipe
>Saving data such as the conditions for the
the mixture or processing of Materials into TOP's inner memory(SRAM)
and then, to read/write in PLC that need the data.
For instance, creates data to write in PLC and then, writes
data values, which are consecutive created from specified device,
it offers the function of reading large quantity of device
values from PLC that is consecutively connected from a
specific device. When power is off, Recipe maintains the data
that are saved last.
|
Pass Through
>Summary: Through the PC or Micom Controllers which connected
COM1 Serial port of XTOP control the PLC which connected COM2
Serial port of XTOP via XTOP.
>Function:
-Download, upload, monitoring the program via COM2 of XTOP
-Direct Communication with Controller via COM1 of XTOP
*Note: It is possible that in case of downloading PLC program
with loader port communication. Downloading from USB,Ethernet
will be developed later.
|
Data Logging
>Collect data of external devices such as temperature
controller and PLC into TOP's memory according to the
conditions for a period an device value. Basically Logging
is saved in SRAM(256KB) or CF Card and Back up in CF card or
USB memoryStick. It is possible to represent log data into graph
using recorder tag and extended graph tag. Also possible to
convert into CSV format which can be used in PC so it is
possible to analyzer data with S/W like Micro Soft Excel.
|
Logging Table
>Display stored logging data as designed
format of table.
-Assignation of title name to each word
-Scroll stored logging data with up&down, right&left direction
-Display stored logging data both SRAM and CF card
-Easy interface to data back up to USB from CF card
through File Manager Program
|
Recorder
>Simple Checking of logged data with graph
-By adding recorder tag, it is possible to represent the
data values, which are saved through the logging function,
in graph and then, monitor the past and the present history.
It is possible to represent the data values, which are saved
through the logging function, and the files, which are saved in not
only the inner memory, but also CF cards, in graph. It is possible
to represent the cursor or the device value and
the time the cursor is located.
|
USB and Ethernet built in
>USB Host/Device built-in
-through USB interface, connect USB
storage(stick) and transfer table.
>High speed transfer with PC through Ethernet
-Upload/Download of program and data communication such
as logging, alarm, and recipe have become fast and simple.
By use of various kinds of Ethernet package software, it
becomes possible to remote-monitor and control from PC.
|
Use Of CF card and USB Memory
>Effective use of CF card and USB Memory
-It is possible to save PLC data in CF card or USB memory,
to convert them into CSV data when necessary, and then, to
make out a daily or a monthly document. (However, in the case of USB,
it is possible to save PLC data only if data are copied from CF card.)
It is possible to save picture, OS, or font files in CF card or USB
memory, and then, to transmit to the TOP's memory. In case, there
are several TOPs, set-up is possible only by transmitting picture program
to each TOP with a CF card or USB memory.
|
Data Management by File List
>Easy Interface Tool from CF Card to USB Memory
-Copy data(Logging, alarm, OS, Fonts, Screen Program)
from CF Card to USB In RUN Mode
-Easy Interface to data back up & Operation by using
USB Memory & CF Card
|
Barcode reader and roll printer
>Communication of Barcode reader and roll printer
-Save ASCII data, which are read through the connection with the
barcode reader, in PLC designated by a user of TOP's inner
memory(SRAM).
It is possible to temporarily designated completion byte which
can confirm that barcode data have been successfully read.
It is possible to print data by connecting with the roll printer.
The above connecting devices all use RS-232C interface
to communicate.
|
 |
XTOP10TV |
XTOP10TS |
XTOP12TS |
XTOP15TX |
| Functional |
| Display Function |
Display Type |
10.4" TFT Color |
12.1" TFT Color |
15" TFT Color |
| Display Area |
211.2 x 158.4mm |
246 x 184.5mm |
304.1 x 228.1mm |
| Resolution |
640 x 480 |
800 x 600 |
1024 x 768 |
| Color |
65,536 Color |
| Backlight Life |
50,000hrs(MIN) |
| Contrast Control |
Touch |
| Brightness |
380cd/m² |
400cd/m² |
380cd/m² |
350cd/m² |
| Touch Function |
Touch Type |
Analog Resistive Film |
| Touch Durability |
1 Million times or more |
| Interface |
Serial |
RS-232C, RS-422/485 |
| Baud rate: Max 115, 200bps |
| Ethernet |
10/100Base-T |
| Printer |
General: HP PCL Level 3 Language/Roll Printer |
| USB |
Built-in: USB 1.1 Compatible |
| CF Card |
Compact Flash Compatible |
| Memory & Clock |
Battery |
Coin type lithium primary cell |
| Backup Memory |
256KB |
| Backup Time Period |
2years or more(at ambient temperatire 25°C) |
| Clock |
Built-in |
| Status LED |
Built-in |
| Screen Memory |
26MB |
| General |
| Power Supply |
Input Voltage |
AC85~264V/DC24V |
| Power Consumption |
20W or less |
25W or less |
| Voltage Sag |
Within 10ms |
| Insulation Resistance |
500V DC, 10M? |
Environment & conditions (Physical/ Mechanical/ Electrical) |
Operation Temperature |
0°C ~ +50°C |
| Storage Temperature |
-10°C ~ +60°C |
| Ambient Humidity |
85%RH or less |
| Atmosphere |
No corrosive gas |
| Vibration Endurance |
Amplitude: 10 <= F <= 25Hz (2G) X,Y,Z direction for 30minutes |
| Noise Immunity |
1500Vp-p (Pulse width 1µs) |
| ESD Immunity |
Contact: ±6KV |
| Shock Endurance |
10G, X,Y,Z direction for 3 times |
| Electricity Endurance |
Conforming to IEC801-2 |
| Ground Connection |
Class 3(100?) |
| Protection Classification |
Conforming to IP65F (*1) |
| Structure |
External Dimension |
305 x 239 x 58 |
316 x 257 x 58 |
366 x 296.5x 58 |
| Panel Cut |
295 x 229 |
307 x 247 |
355 x 286 |
| Weight |
2.3KG |
2.5KG |
3.2KG |
| Cooling System |
Natural air circulation |
| Case Material |
ABS (Resistance to flame) |
| (*1): Although we confirm the IP65F Conformity